Intraouclar Lens (IOLs)

Hydrophobic Acrylic
Hydrophobic Acrylic Technical Details

Preloaded Injector and Cartridge

Features of IOL Material:

The material has been selected to create a balance between high refractive index, foldability for small incision and fast unfolding time. the key requirement for a good hydrophobic lens.

Aspheric IOL:

For better contrast sensitivity, better mesopic vision Aspheric IOLs attempt to improve pseudo-phobic vision by controlling spherical aberrations.

360o Square Edge IOL:

The Rounder Anterior Edge scatters light which can reduce internal reflections. The slopping side edge minimizes potential for edge glare. The squared posterior edge facilitates 360o Capsular contact.

Angulated haptics to allow for adequate papillary clearance and adhesion to the posterior capsule.

Features of IOL:

Glistening Free.
Good resistance to YAG loser.
Easy to handle.
Less Mechanical / YAG laser damage.
Low PCO rates.

Note:

The optimized A-constants are approximated based on statistical corelation between calculated and absorbed refractive error after ocular implantation.

These optimized optical constant as derived based on surgeons experience and contribution to the collated data.

PMMA Intraocular Lens

PMMA Intraocular Lens Technical Specification.

PMMA Iris Claw Intraocular Lens

PMMA Iris Claw Intraocular Lens Technical Specifications

Square Edge Aspheric Intracular Lens

Aspheric IOL:

For better contrast sensitivity, better mesopic vision Aspheric IOLs attempt to improve pseudo-phobic vision by controlling spherical aberrations.

Strategy 1:

Lenses with negative spherical aberrations to balance the normally positive corneal spherical aberrations.

Strategy 2:

Lenses with minimum spherical aberrations, so that no additional spherical aberration is added to the corneal spherical aberration.

360o Square Edge IOL:

Square Edge IOL
1. The Rounder Anterior Edge scatters light which can reduce internal reflections.
2. The Sloping Side Edge minimizes potential for edge glare.
3. The Squared Posterior Edge facilitates 360o Capsular Contact.

Angulated haptics to allow for adequate pupillary clearance and adhesion to the posterior capsule

Note: The optimized A-constants are approximated based on statistical correlation between calculated and absorbed refractive error after ocular implantation.


Premium IOLs

Diffractive-Refractive Multifocal Hydrophobic Intraocular Lens

Diffractive-Refractive Multifocal Hydrophobic Intraocular Lens Technical Specification.

Diffractive-Refractive combination Multifocal IOL designed to maximize the patients ranged of Vision.
Diffractive-Refractive combination Multifocal IOL to provide patients with a full range of vision under most lighting conditions.

Diffractive-Refractive Multifocal Hydrophilic Intraocular Lens

Diffractive-Refractive Multifocal Hydrophilic Intraocular Lens Technical Specification.

Posterior Diffractive Surface. Anterior Aspheric Surface with 360o Square Edges.
RNI Ennergy distribution for Far and Near Focus 60740.